- Abstract
- A specially developed wide-field digital microarray analyzer was used for quantitative estimation of weak signals from biochip cells with the fluorescence intensity comparable to that of the substrate material. Luminescence intensity of the different material surfaces that could serve as substrates for biochip matrices used in medical diagnostics was measured in the spectral range of the cyanine dye Cy5 (λex = 645 nm, λem = 665 nm). It was shown that the developed digital microarray analyzer allowed recording the dye Cy5 on a substrate made of black polybutylene terephthalate (black crastin) with concentration of 3 or more molecules/μm2.
- Keywords
- биочипы люминесценция анализатор изображения биочипов
- Date of publication
- 24.10.2025
- Year of publication
- 2025
- Number of purchasers
- 0
- Views
- 20
References
- 1. https://www.rsc.org/journals-books-databases/aboutjournals/lab-on-a-chip/
- 2. Ozer T., McMahon C., and Henry C. S. Advances in paper-based analytical devices. Ann. Rev. Anal. Chem., 13 (1), 85–109 (2020). DOI: 10.1146/annurev-anchem- 061318-114845
- 3. http://www.moslabo.ru/production/oborudovanie-ipribory-dlya-laboratorii-molekulyarnoj-biologii/
- 4. Колчинский А., Грядунов Д., Лысов Ю., Михайлович В., Наседкина Т., Турыгин А., Рубина А., Барский В. и Заседателев А. Молекуляр. биология, 38, 4–13 (2004)
- 5. http://www.biochip.ru/lab/apps/tb-biochip.html#:~:tex
- 6. http://www.biochip-imb.ru/index.php/test-systems/pathogens/9-hcv-biochip
- 7. Fesenko D. O., Chudinov A. V., Surzhikov S. A., and Zasedatelev A. S. Biochip-based genotyping assay for detection of polymorphisms in pigmentation genes associated with cutaneous melanoma. Genet. Test. Mol. Biomarkers, 20 (4), 208–212 (2016). DOI: 10.1089/gtmb.2015.0272
- 8. Shaskolskiy B., Kravtsov D., Kandinov I., Gorshkova S., Kubanov A., Solomka V., Deryabin D., Dementieva E., and Gryadunov D. Comparative whole-genome analysis of Neisseria gonorrhoeae isolates revealed changes in the gonococcal genetic island and specific genes as a link to antimicrobial resistance. Front. Cell. Infect. Microbiol., 12, 831336 (2022). DOI: 10.3389/fcimb.2022.831336
- 9. Фесенко Д. О., Ивановский И. Д., Иванов П. Л., Земскова Е. Ю., Поляков С. А., Фесенко О. Е., Филиппова М. А. и Заседателев А. С. Универсальная панель инсерционно-делеционных полиморфизмов ChipID106 для генетической идентификации личности и биочип на ее основе. Молекуляр. биология, 57 (4), 632–646 (2023). DOI: 10.31857/S0026898423040067
- 10. Фесенко Д. О., Ивановский И. Д., Иванов П. Л., Земскова Е. Ю., Агапитова А. С., Поляков С. А., Фесенко О. Е., Филиппова М. А. и Заседателев А. С. Биочип для генотипирования полиморфизмов, ассоциированных с цветом глаз, волос, кожи, группой крови, половой принадлежностью, основной гаплогруппой Y-хромосомы, и его использование для исследования славянской популяции. Молекуляр. биология, 56 (5), 860–880 (2022).
- 11. Lysov Y., Barsky V., Urasov D., Urasov R., Cherepanov A., Mamaev D., Yegorov Y., Chudinov A., Surzhikov S., Rubina A., Smoldovskaya O., and Zasedatelev A. Microarray analyzer based on wide field fluorescent microscopy with laser illumination and a device for speckle suppression. Biomed. Opt. Express, 8 (11), 4798–4808 (2017). DOI: 10.1364/BOE.8.004798
- 12. http://www.biochip-imb.ru/index.php/biochip-reader/imageware
- 13. https://www.moslabo.ru/production/oborudovanie-ipribory-dlya-laboratorii-molekulyarnoj-biologii/sistemy-vizualizacii-kletok-dlya-laboratorii/bioscience-media-fluorowatcher-fluorescentnyj-imedzher-dlya-fotografirovaniya-svetyashchihsya-molekul/